ETP-HYLOC®DimensionsTransmittable torque or axial force at 1000 barHPolar moment
of inertia
J
kgm2 • 10-3
Weight
kg
Shaft h7Shaft h8Min hub DH mm
d
mm
D
mm
D1
mm
L
mm
L1
mm
T
kNm
FA
kN
T
kNm
FA
kN
Yieldpoint N/mm2
>300>400
50507710156822,6702,470110105M83,22,4
60608911364904,61304,3130140125M85,43,1
7070102122741007,92107,4200170145M88,74,1
80801151358411012,129011,5280200160M8145,4
90901281489412017,138016,2360235180M12237,0
10010014016010413024,248523,1460270200M12348,6
11011015417311414032,959531,5570295220M125111
12012016818612415043,272041,6690320240M127614
13013018220013416053,882551,4790350260M1611017
14014019621314417068,998566,2945375280M1615021
15015021022715418085,4113582,31095400300M1621025
16016022424016419010413051001260425320M1629030
18018025226718421015016751461625480360M1650042
20020028029320423020620602002000535400M1683056
22022030832022425027324852662415585435M16130073
T = Transmittable torque when axial force is 0.H: Threads for easy handling.
Dimension subject to alterations without notice.
FA = Transmittable axial force when torque is 0.
DH = Outer diameter for hub material in steel.