ETP-®DimensionsTransmittableScrews**
DIN 912, 12.9
Bores 2xH
suitable for
MC6S screws
Polar moment
of inertia
J
kgm2 • 10-3
Weight
kg
torqueaxial forceradial force
d
mm
D
mm
D1
mm
D2
mm
L
mm
L1*
mm
T
Nm
FA
kN
FR
kN
Dim.R
mm
N
mm
Tt
Nm
D3
mm
Screw
Dim.
151520515521356072M1017,15836M50,060,19
1919265458274110084M1018,25840M50,080,23
3/4”19,05265458274110084M1018,25840M50,080,23
20202755592842130114M1018,95841M50,090,24
22222958622943210154,8M1020,55843,5M50,110,27
24243264703347230155,6M1022,75848M60,170,34
25253367723448300206M1023,25850M60,210,38
1”25,43367723448300206M1023,25850M60,210,38
28283770763549325207,2M1024,95853,5M60,260,43
30303972803650530268M10265855,5M60,290,45
1 1/431,754385923858550268,8M163182564,5M80,730,82
32324385923858550268,8M163182564,5M80,730,82
353546889440609004010M1632,482567M80,850,88
3838509096446411504711,2M1633,182570M80,940,92
1 1/2" 38,1509096446411504711,2M1633,182570M80,940,92
40 "40539196476712004712M1634,282572M81,01,0
T= Transmittable torque when axial force is 0.}   When the screw is tightened to Tt.Tt= Recommended tightening torque for the screws.
Further tightening does not increase the pressure.
* D2 is valid before mounting.
Dimensions subject to alterations without notice.
FA=Transmittable axial force when torque is 0.
FR=Max transmittable radial force at continuous operation.
Max allowed bending torque: 10% of transmittable torque T.